Written on: August 1, 2026 by W. Stephen Tait
Hello, everyone. Corrosion is everywhere and it’s expensive. Indeed, the estimated cost of worldwide corrosion services—testing, consulting, inhibitor/coating/laminated films for control and prevention—is expected to hit $3.48 trillion by the end of 2026.
The spray packaging corrosion risk is always greater than zero and as high as 62%, particularly when there is no corrosion data for a new formula or derivatives of current formulas (line extensions).
Two types of corrosion tests are available for spray packaging:
1. Traditional long-term storage stability tests
2. Electrochemical corrosion tests
Figure 1 depicts the corrosion risks associated with each of these tests as a function of test length.

The storage test curve in Figure 1 is from one-year-old package examinations for pitting corrosion of approximately 7,500 aluminum, tin-plated steel and tin-free steel aerosol containers (approximately 750 to 1,000+ storage tests). The electrochemical test curve in Figure 1 was generated from over 1,500 direct comparisons between predictions from Aristartec corrosion test results and actual package corrosion.
Notice in Figure 1 that risk decreases as the test length increases. Thus, results from a short storage test typically have a higher risk than results from a long storage test. In other words, storage test risk decreases as the amount of corrosion data increases with increasing test time. This is why I recommend conducting storage tests for at least one year before making a “Go/No-go” decision to commercialize new products or derivative products.
Figure 1 also illustrates that the risk for a properly-designed:
• Storage test typically decreases from 62% to around 7% after one year of testing
• Electrochemical test typically decreases from 62% to < 1% within 90 days of testing
In other words, an electrochemical test can be completed in a significantly shorter time than a storage test with a corresponding lower risk.
Why corrosion risk is always a concern
Small changes to a formula’s chemical composition can cause very large changes in corrosion behavior. For example, changing to a new fragrance or a new surfactant in a non-corrosive formula sometimes results in a corrosive new derivative product.
Corrosion can unexpectedly appear with changes in the concentrations of formula ingredients, either by design or from manufacturing batch-to-batch variations. For example, an inhibitor can lose its effectiveness when its concentration is either above or below the effective concentration range. Also, contaminants, such as water in anhydrous formulas, are a common cause for spray package corrosion.
Substituting formula ingredients from alternate suppliers could also cause unexpected corrosion in spray packaging.
Variability in formula ingredients, formula ingredient concentrations, package components and materials-of-construction also causes random corrosion in some instances.
Major elements of control & prevention
Figure 2 provides a diagram for the major elements of a corrosion control and prevention program. Corrosion testing is the linchpin of any comprehensive corrosion control and prevention program; it determines formula compatibility with metal and plastic package components, package metals and coatings.

Figure 2 implies that one doesn’t have to abandon a corrosive formula. In most instances, a corrosion inhibitor can be developed to transform a corrosive formula to a non-corrosive one. However, corrosion inhibitors typically have an effective concentration range, above or below which the inhibitor could actually cause corrosion. Coatings in some instances can also inhibit or prevent corrosion.
Corporate knowledge and an experience database can also help avoid formula-package combinations and formula ingredients that have a high probability of causing spray package corrosion. Such a database can also help reduce the number and length of corrosion tests in some situations.
“Knowledge + Experience” are shown in Figure 2 with a plus sign (+) between them to emphasize that they are interconnected. Knowledge without practical experience, and experience without theoretical frameworks, are incomplete and will not result in useful, predictive professional practice. In other words, experience and knowledge work together to complete a comprehensive corrosion control and prevention program.
Corrosion control and prevention are typically not part of most corporate business plans or mission statements, but product efficacy, quality and safety are! Ignoring corrosion risk could lead to a major disruption of business plans with a corresponding loss of income; re-deployment of resources to determine the cause and find a solution may also delay other projects.
Ignoring risk can also result in either an expensive product recall or litigation with subsequent potential loss of future sales when customers/consumers lose confidence in products; the liability for product recalls with litigation can range from $43 million–$196 million. A comprehensive corrosion control and prevention program also helps prevent the loss of productivity and expense that accompany both in-development and in-market product failures. Consequently, corrosion testing is significantly cheaper than both in-development and in-market corrosion failures.
It bears repeating: corrosion prevention and control should be a continuous process and not a one-time event.
Thanks for your interest and I’ll see you in November. Contact me at 608-831-2076; rustdr@pairodocspro.com or from our two websites: pairodocspro.com and aristartec.com. SPRAY